How To Do A Compaction Test Or In-Situ Density Test?

The consultant representative or the quality engineer shall select the area to be tested and shall mark on the drawing.
There are many ways to determine the compaction of soil but widely being used Sand Replacement Methodwhich we are using on our site. And before blinding works, you have to make sure that the inspection request is submitted to the consultant and compaction test report is passed.
But first, here are the apparatus and equipment for the In-situ density test.
Apparatus for In-Situ Density Test
1. Pouring Cylinder7. Meter
2. Pointed Steel Rod8. Hammer
3. Large Screw Driver9. Bent spoon dibber
4. Sand or Silica Container10. Gloves
5. Glass plate11. Metal trays, 500mm square, 50mm depth with 200mm dia. hole in the center
6. Sample container (plastic bag or plastic container)
Here are the procedure on how to do the Compaction test or In-Situ Density test.
1. Place the metal tray. The technician can now place the metal tray as per Consultant or Quality Engineer preferred location. As a Quality Engineer, you should make sure that the area to be tested is compacted and within the area submitted in the Inspection Request.
placingthemetaltray.png
2. Marking the sample container. As QC Engineer, you should see to it that the sample container is marked by a technician of its location and other related markings, just make sure all the marks are correct .
Marking the container3. Digging the soil.  A helper will start to dig the soil by a using pointed steel rod (250mm long 16 – 20 mm dia.) and a hammer. The head of the rod shall be stricken at slow speed and at conditional pressure. Use gloves for hand protection to prevent hand injury.
Digging the soil
4. Putting the loose soil in the sample container. The dug loose soil shall be placed in the sample container, make sure there are no any pieces of soil shall be wasted otherwise, it will affect the results of compaction.
taking the soil
5. Measuring the depth of hole. While the digging progresses, monitor the depth of hole by measuring a ruler, make sure that the depth is 200 mm or 150 mm depending on the requirement of the specification. If the depth is not yet achieved continue digging until it reach the desired or required depth.
Measuring the deep of hole
 6. Pouring silica in the hole. Once the hole is properly shaped to the diameter of 200 mm just the same diameter that of the hole of the metal tray and the depth has reached. Place the pouring cylinder onto the metal tray. Pour the silica inside the pouring cylinder make sure no one will hold or touch the pouring cylinder that may cause vibration.
Pouring the silica
7. Taking the silica from the hole. The hole, once filled with silica and when the hole has fully filled, remove the silica and place it to extra container it may use again for the next set of compaction.
Taking the silika

Here are now the formulas to compute the compaction test or In-situ density test.
Det. the bulk density of Sand.
densityofsand.jpg
 Where,
themassofsandrequiredtofilltheexcavatedhole.jpg
Formula for Bulk Density of Sand
ρsBulk density of sand (Mg/m³)
MsMass of sand to fill the container (in gm.)
VVol. of container (in mL)
M1Mass of sand before pouring in the container (in mg.)
M2Mass of sand in cone (in gm.)
M3Mass of sand after pouring the container (in gm.)
Det. the bulk density of soil.

bulkdensityofsoil.jpg
where,
theformulaformassofsand.jpg
Bulk Density of Soil
ρsoBulk density of soil (Mg/m³)
MeMass of soil excavated (in gm.)
MfMass of sand required to fill the hole (in gm.)
M1Mass of sand before pouring into the hole (in gm.)
M2Mass of sand in cone (in gm.)
M4Mass of sand after pouring into the hole (in gm.)
Det. the dry density.
thedrydensityofsoil.jpg
Det. the degree of compaction.
degreeofcompaction.jpg
Hoping that the above have helped the Quality Engineers or civil Engineers to better understand how the compaction test or In-situ density test using the sand replacement method is done.

Comments

Popular posts from this blog

Classifying Soils for Highway Construction with AASHTO M145 / ASTM D3282

Checklists for Quality Control Documents (QCD)

Inspection Testing Plan (ITP) VS Checklist